102 products · Allen-Bradley

Allen-Bradley 1794-IA16
$310.00

Allen-Bradley 1794-IA8
$306.00

Allen-Bradley 1794-IA8I
$790.00

Allen-Bradley 1794-IB10XOB6
$238.00

Allen-Bradley 1794-IB10XOB6XT
$573.99

Allen-Bradley 1794-IB16
$240.99

Allen-Bradley 1794-IB16D
$339.99

Allen-Bradley 1794-IB16XOB16P
$346.99

Allen-Bradley 1794-IB32
$284.00

Allen-Bradley 1794-IB8
$169.00

Allen-Bradley 1794-IC16
$1,171.00

Allen-Bradley 1794-IM16
$490.99

Allen-Bradley 1794-IM8
$463.99

Allen-Bradley 1794-IV16
$171.00

Allen-Bradley 1794-IV32
$923.99

Allen-Bradley 1797-IBN16
$739.99

Allen-Bradley 2080-IQ4
$116.99

Allen-Bradley 2085-IA8
$208.00

Allen-Bradley 2085-IQ16
$225.00

Allen-Bradley 2085-IQ32T
$275.99
Allen-Bradley 5069-IA16
$481.00

Allen-Bradley 5069-IB16
$479.99

Allen-Bradley 5069-IB16F
$565.00

Allen-Bradley 5069-IB16K
$635.00
Browse by manufacturer
Related families and series
Product families
- Allen-Bradley Distributed I/O (45)
- EtherCAT Terminals (36)
- Siemens — Miscellaneous Parts (21)
- Siemens PLCs (17)
- ControlLogix (15)
- CompactLogix (14)
- X20 System (13)
- MELSEC PLCs (12)
Series
- EL Series Terminals (26)
- Siemens Misc Catalog Parts (21)
- ControlLogix 1756 I/O Modules (15)
- FLEX I/O (15)
- POINT I/O (14)
- X20 I/O Modules (13)
- SLC 500 I/O Modules (1746) (11)
- EP Box Modules (9)
What are Digital Input Modules?
Digital input modules serve as the interface between field devices and a programmable logic controller (PLC) or distributed control system (DCS). They convert discrete signals—binary "on" or "off" states—from devices like pushbuttons, limit switches, proximity sensors, and pressure switches into logic levels the processor can interpret. These modules provide electrical isolation (optocoupling) to protect sensitive PLC circuitry from voltage spikes and noise on the plant floor.
Main Manufacturers
We stock a comprehensive inventory of digital input modules from the industry’s most reliable brands:
- Allen-Bradley: Including the Bulletin 1756, 1769, and 1734 series.
- Siemens: SIMATIC S7-1200, S7-1500, and ET 200SP distributed I/O.
- Beckhoff: EtherCAT Terminals (EL series) and Bus Terminals (KL series).
- Mitsubishi Electric: MELSEC iQ-R and iQ-F series.
- Schneider Electric: Modicon M221, M241, and Lexium series.
- B&R Industrial Automation: X20 System modules.
- Additional Stock: Omron (CJ1W/NX), GE Fanuc (Series 90-30), ABB (S500/S800), and Delta Electronics (DVP series).
Typical Applications
Digital input modules are essential in virtually every automated environment. Common use cases include:
- Machine Safety: Monitoring E-stop buttons and light curtains.
- Material Handling: Sensing the presence of packages on a conveyor via photoelectric sensors.
- Process Control: Receiving status signals from motor starters or valve limit switches.
- Packaging: Counting pulses from high-speed sensors for throughput tracking.
Selection Guide
When selecting a digital input module, technical specifications must align with the existing system architecture:
- Voltage Rating: Match the module to the field device voltage (e.g., 24V DC, 120V AC, or 230V AC).
- Logic Type: Determine if you require Sinking (NPN) or Sourcing (PNP) configurations.
- Point Density: Balance space constraints with wiring complexity (choose from 8, 16, 32, or 64-channel modules).
- Signal Response Time: For high-speed applications like bottling or precision CNC, select "Fast Response" modules with lower input filter times.
- Connection Type: Removable Terminal Blocks (RTBs) are preferred for high-uptime environments to allow for rapid module replacement without rewiring.
Replacement & Compatibility
Migrating from legacy systems often requires specialized I/O conversion. For example, replacing a GE Fanuc 90-30 system with an Emerson PACSystems RX3i can often utilize existing wiring. Similarly, when moving from Allen-Bradley SLC 500 (1746) to CompactLogix (1769 or 5069), check for compatible conversion kits that map old terminal blocks to new module footprints. For distributed I/O, check support for protocols like PROFINET, EtherNet/IP, or EtherCAT to ensure cross-brand communication.
Related guides
This engineering guide details the path for upgrading obsolete 1756-L61 controllers to modern 1756-L71 or 1756-L81E modules, focusing on hardware, network, and firmware mapping.
Transitioning from legacy Allen-Bradley 1769 CompactLogix to the high-performance 5069 L3 platform requires deliberate planning. This technical guide outlines hardware, wiring, and code migration steps.
This technical guide details the migration pathway for legacy Allen-Bradley 1769-L32E controllers. Learn how to address software conversion, physical footprint modifications, and communication standard changes.
Transition your legacy Allen-Bradley 1756-L63 controller to modern ControlLogix 5580 hardware. This guide details direct replacement paths, firmware considerations, and software migrations.
Frequently asked questions
What is the difference between standard and high-density digital input modules?
Digital input modules process binary "on/off" signals (1 or 0). High-density modules typically offer 16, 32, or 64 points per card, reducing the physical footprint in the control cabinet. Standard modules usually range from 4 to 16 points. Choosing high-density modules requires careful consideration of terminal block wiring and heat dissipation.
How do I choose between Sinking (NPN) and Sourcing (PNP) digital inputs?
Sinking (NPN) inputs require the field device to provide a path to ground, while Sourcing (PNP) inputs require the field device to provide the positive voltage. In most European and North American systems, PNP (Sourcing) is the standard for safety and troubleshooting clarity. Always match the module type to your sensor's output transistor type.
What are the most common voltage ratings for digital input modules?
The most common voltage for industrial automation is 24V DC due to safety and compatibility with electronic sensors. However, 120V AC and 230V AC modules are still widely used in infrastructure, motor control centers (MCCs), and legacy systems where long-distance signal runs or high-interference environments are present.
Can I use a digital input module from a different brand than my PLC?
Yes, many modern remote I/O systems allow for cross-manufacturer communication. For example, a Beckhoff EtherCAT terminal or a Phoenix Contact Contactron system can be integrated into a Siemens (PROFINET) or Allen-Bradley (EtherNet/IP) network using the appropriate bus coupler. However, local chassis-based modules must match the specific PLC backplane.
How do I troubleshoot a faulty digital input point?
When a module fails, check the "Module OK" and individual "I/O Status" LEDs. If the LED is on but the PLC logic doesn't see the signal, the issue may be backplane communication. If the LED is off, check for 24V DC at the terminal or a blown internal fuse. Many Allen-Bradley ControlLogix modules offer "Diagnostic" versions (e.g., 1756-IB16D) that pinpoint open-wire or short-circuit conditions automatically.
Machine down? Get a fast quote on the parts you need.
New, surplus, and refurbished industrial automation options. Request a quote or speak directly with an automation specialist for emergency sourcing.