What the 6SL3120-1TE32-0AA4 does, where it fits in a SINAMICS S120 booksize system, how to size and install it, and how to buy it available to quote.
The Siemens 6SL3120-1TE32-0AA4 is a SINAMICS S120 Single Motor Module rated 32 A on a 600 V DC link. It is the axis-side power stage of a booksize drive system: the Line Module rectifies incoming AC into the common DC bus, and each Motor Module converts that DC into the controlled three-phase output for one motor.
We keep this part available to quote for immediate dispatch β see the live listing and pricing on the Siemens 6SL3120-1TE32-0AA4 product page.
Quick answer
| Question | Answer |
|---|---|
| What is it? | SINAMICS S120 Single Motor Module (booksize) |
| Output current | 32 A |
| DC link voltage | 600 V DC |
| Axes controlled | 1 |
| Control | Requires a Control Unit (CU320-2 family) |
| Availability | available to quote at Palm Parts Solution |
Where it sits in a SINAMICS S120 system
A booksize line-up is built left to right:
- Line Module (Smart or Active) feeds the DC bus.
- Motor Modules clip onto the DC bus busbars β one module per axis.
- A Control Unit runs the closed-loop control over DRIVE-CLiQ.
- DRIVE-CLiQ cabling carries motor encoder and module identification data.
The 6SL3120-1TE32-0AA4 is the single-axis member of that line-up. For two smaller axes in the same width, Siemens uses Double Motor Modules instead; for one larger axis, you move up the current rating rather than paralleling modules.
How to size it correctly
- Match continuous current, not motor kW alone. Compare the motor rated current against the 32 A continuous rating, then confirm the overload profile your cycle demands.
- Check the DC link. The module expects a 600 V DC bus from a matched Line Module; feeding it from an unmatched supply is the most common commissioning failure.
- Add up the bus. The Line Module must cover the sum of simultaneous axis loads, not the largest axis.
- Plan cooling. Internal air cooling needs the specified free space above and below the module inside the cabinet.
Installation and commissioning checklist
- De-energise and verify the DC bus is fully discharged before touching busbars.
- Slide the module onto the DC link busbars and torque the connections to the Siemens-specified values.
- Chain DRIVE-CLiQ from the Control Unit through each module in a defined order β the topology is stored and compared at power-up.
- Connect the motor encoder through the corresponding DRIVE-CLiQ or sensor module.
- Commission with STARTER or TIA Portal / Startdrive, then save the parameter set to the memory card.
Common failure symptoms
- Repeated overcurrent trips β usually undersized module for the duty cycle, or a motor cable insulation fault.
- DRIVE-CLiQ topology error at power-up β a module was replaced or re-ordered without accepting the new topology.
- Overtemperature warnings β blocked cabinet airflow or clogged filters, not a failed module.
- Dead axis with a healthy Line Module β isolate by swapping the axis onto a known-good module before ordering parts.
Replacing a failed 6SL3120-1TE32-0AA4
Replace like for like where possible: keep the same current rating, the same DRIVE-CLiQ position and the same firmware family as the rest of the line-up. After swapping, accept the topology on the Control Unit and reload the saved parameter set so the axis returns with its original tuning.
Buy it with the part available to quote
Unplanned drive failures stop the line, so lead time matters more than catalogue price. Palm Parts Solution holds the 6SL3120-1TE32-0AA4 available to quote, ships free across the USA and delivers worldwide, with support available 24/7.
- Check price and availability: Siemens 6SL3120-1TE32-0AA4
- Need several axes or a full booksize line-up? Request a quote
- Browse the full range: Siemens parts
Parts that fix this
Parts covered by this article β request current availability, free USA shipping.