Free Shipping Across the USA — Worldwide Delivery Available!
PALM Parts Solution
AccountQuote

REPLACEMENT GUIDES

25B-D024N104 Replacement Guide — PowerFlex 525

Worldwide Shipping
Fast Dispatch
Warehouse Pickup
1-Year Warranty

In Short

The 25B-D024N104 is a 15 HP / 11 kW (24 A normal / 17 A heavy duty), 380–480 V AC, 3-phase PowerFlex 525 AC drive, Frame D, NEMA Open / IP20. If yours has failed, the direct-form-fit replacement is another 25B-D024N104. Functional alternates include 25B-D037N104 (same rating, different option configuration). PALM Parts Solution stocks new, refurbished, and surplus units with a 1-year warranty and same-week dispatch.

Symptoms (when this unit needs replacement)

  • Repeated trips on F005, F006 after a full power-cycle and parameter reset
  • DC bus capacitor bulge or electrolyte leakage on the back of the chassis
  • Cooling fan stall with subsequent IGBT overtemp shutdown
  • Loss of EtherNet/IP heartbeat to the ControlLogix/CompactLogix master
  • Smoke or burnt-PCB odor from the heatsink vents (replace immediately — do not power on)

Causes

  • DC bus capacitor aging — typical 7–10 yr life at 40°C ambient; common after a long idle period followed by re-energization
  • IGBT module failure from sustained operation near thermal limits or undersized line reactor
  • Single-phase input caused by a blown upstream fuse — drive runs but trips on overload/overcurrent under load
  • Firmware corruption after a brownout during a flash update
  • Cooling fan EOL — bearing wear; once airflow drops below spec the drive thermal-trips

Troubleshooting before you replace

  1. Record the active fault code and the value of parameter P947 (last 8 faults). Cross-reference to: F005, F006, F013, F029.
  2. Measure all three input phases at the drive terminals — a missing phase masquerades as overcurrent.
  3. Disconnect the motor and run the drive in no-load / sensorless test mode. If it still trips, the fault is internal.
  4. Inspect DC bus capacitors visually; check bus voltage at the test points (≈ 1.41 × line voltage).
  5. Verify cooling fan rotation and inlet temperature; clear heatsink debris.
  6. If the drive faults only over the network, isolate by running from the local HIM and confirm the issue is comms, not power.

Replacement Options

OptionPart NumberNotes
Direct replacement25B-D024N104Same form-fit-function — drop-in. Re-flash the saved parameter set / runtime image.
Alternate 125B-D037N104Same electrical rating with a different option configuration (HIM, communications, or filter).
Alternate 225B-D017N104Same electrical rating with a different option configuration (HIM, communications, or filter).
Alternate 322B-D024N104Same electrical rating with a different option configuration (HIM, communications, or filter).
Like-for-like upgradeFamily migration — see the PowerFlex 525 family pageRecommended when the original is end-of-life.
  • All in-stock 25B-D024N104 units → /product/25b-d024n104
  • 25B-D037N104 listings → /product/25b-d037n104
  • 25B-D017N104 listings → /product/25b-d017n104
  • Full PowerFlex 525 catalog on PALM

FAQ (FAQPage schema)

Q: Is 25B-D024N104 discontinued?
A: The PowerFlex 525 platform remains active in the Rockwell catalog at the time of writing, but specific option-string SKUs are reaching end-of-life. PALM Parts Solution stocks new, refurbished, and surplus 25B-D024N104 units to keep your machine running until you plan a controlled migration.

Q: What is a direct drop-in replacement for 25B-D024N104?
A: Another 25B-D024N104 with matching firmware family is the only true drop-in. The closest functional alternate is 25B-D037N104 — same 15 HP / 11 kW rating, different option configuration. Plan parameter file transfer either way.

Q: Will a PowerFlex525 parameter file from my old drive load into the new one?
A: Yes, when the firmware major revision matches. Use Connected Components Workbench or DriveExecutive to save the .dno file from the old drive, then download to the replacement. Verify motor nameplate parameters before the first run.

Q: How is 25B-D024N104 rated — heavy duty or normal duty?
A: This catalog code is rated for 24 A normal / 17 A heavy duty (15 HP / 11 kW) at 380–480 V AC, 3-phase. For 150% overload applications (conveyors, hoists, positive-displacement pumps) confirm the heavy-duty column on the Rockwell selection guide.

Q: What does the most common F005 fault on this drive indicate?
A: F005 is typically caused by regenerative energy during deceleration, an oversized DC bus capacitor bank degrading, or input overvoltage. Confirm deceleration ramp and add a brake resistor or dynamic brake module when the load has inertia.

Shop the parts in this guide

Browse in-stock inventory for the products covered by this article.

Need a specific part?

Send us your part numbers — we'll respond the same business day with pricing and availability.

Are you an Electrical Distributor?Learn more about our distributor program

PALM Parts Solution sells used surplus products. PALM Parts Solution is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by PALM Parts Solution come with PALM Parts Solution's 1-Year Warranty and do not come with the original manufacturer's warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.

Read full disclaimer →