Free Shipping Across the USA — Worldwide Delivery Available!
PALM Parts Solution
AccountQuote
In Stock Fast Shipping Available
Pepperl+Fuchs KFD2-ST3-Ex2 2-channel isolated barrier for industrial safety

*Image shown is a representation only. Actual product may vary.

Pepperl+Fuchs KFD2-ST3-Ex2

by Pepperl+Fuchs

Read verified buyer reviews ↓

OverviewThe Pepperl+Fuchs KFD2-ST3-Ex2 is a robust 2-channel isolated barrier engineered to facilitate the secure transmission of digital signals from hazardous industrial environments to safe area control systems. This essential device seamlessly integrates with NAMUR sensors or dry contacts, ensuring both data integrity and operational safety in demanding settings. Each channel incorporates an active transistor output, guaranteeing precise and reliable signal communication. A cornerstone of its design is the comprehensive galvanic isolation implemented between the input, output, and power supply, effectively mitigating electrical interference and bolstering overall system protection. The KFD2-ST3-Ex2 features advanced line fault detection (LFD) capabilities, proactively identifying issues such as lead breakage and short-circuit conditions. Its reversible operational mode, easily configured via DIP switches, offers exceptional flexibility to adapt to a variety of application requirements. Furthermore, this switch amplifier holds SIL 2 certification in accordance with IEC/EN 61508, highlighting its commitment to high reliability and adherence to stringent safety standards for critical operations.Key Features Input Versatility: Compatible with both dry contacts and NAMUR sensors, offering wide application suitability. Dual Channel Design: Provides two independent channels for efficient signal processing. Active Transistor Output: Ensures stable and dependable signal switching. Superior Isolation: Features galvanic isolation across input, output, and power supply for enhanced safety and reduced interference. Advanced Diagnostics: Integrated Line Fault Detection (LFD) for rapid identification of wiring issues, including lead breakage and short-circuits. Configurable Operation: Reversible mode of operation via DIP switches allows for application-specific customization. Safety Certified: SIL 2 certified as per IEC/EN 61508, guaranteeing high integrity in safety instrumented systems. Compact and Durable: Housed in a slim 20 mm enclosure with IP20 protection, perfectly suited for DIN rail mounting. Broad Operating Temperature: Functions dependably in ambient temperatures ranging from -20 °C to +60 °C. Global Compliance: Multiple approvals, including ATEX, IECEx, UL, CE, and UKCA, ensure suitability for international markets. Flexible Powering: Operates on 19–30 V DC via Power Rail or dedicated terminals. Technical Specifications Signal Type: Digital Input Input Connections: Terminals 1+, 2+, 3- (Channel I); 4+, 5+, 6- (Channel II) Output Connections: Output I: terminal 7+; Output II: terminal 9+ Open Circuit Voltage/Short-Circuit Current: Approximately 10 V DC / approximately 8 mA Switching Point/Hysteresis: 1.2–2.1 mA / approximately 0.2 mA Line Fault Detection (LFD) Thresholds: Breakage: I ≤ 0.1 mA; Short-Circuit: I ≥ 6.5 mA Response Time: ≤200 µs Switching Frequency: ≤5 kHz Rated Output Voltage: 30 V DC Rated Output Current: 100 mA Signal Level (Output): 1-Signal: (Supply voltage) - 3 V max. for 100 mA; 0-Signal: Blocked output (off-state current ≤10 µA) Galvanic Isolation: Input/Output and Input/Power Supply: Reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V_eff Indicators: LEDs for power supply, output status, and line fault alerts Configuration: DIP switches located on the device Mounting: 35 mm DIN rail (EN 60715) Dimensions (W×H×D): 20 × 119 × 115 mm Protection Class: IP20 Ambient Temperature Range: -20 °C to +60 °C Weight: Approximately 150 g Part Number: 262111 Applications Process Automation Systems: Essential for dependable signal transfer in sophisticated control loops. Chemical and Petrochemical Industries: Designed to meet the stringent safety requirements of potentially explosive atmospheres. Oil and Gas Facilities: Ensures secure operation and monitoring in both onshore and offshore environments. Pharmaceutical Manufacturing: Crucial for maintaining safety and operational integrity in sensitive production processes. Water and Wastewater Treatment Plants: Provides reliable signal isolation in critical infrastructure. Why Choose the Pepperl+Fuchs KFD2-ST3-Ex2?Opting for the Pepperl+Fuchs KFD2-ST3-Ex2 means investing in an isolated barrier that prioritizes safety, reliability, and versatility. Its SIL 2 certification assures integrity in critical safety instrumented systems, while advanced features like line fault detection minimize downtime and enhance diagnostic capabilities. The compact design and broad operating temperature range make it suitable for diverse industrial settings. With global compliance and flexible configuration options, this device offers a robust solution for securing digital signal transmission in hazardous areas.Order NowEnhance the safety and efficiency of your industrial operations. Purchase the Pepperl+Fuchs KFD2-ST3-Ex2 today to ensure reliable signal transfer in challenging environments.FAQWhat is the primary function of the Pepperl+Fuchs KFD2-ST3-Ex2?Its primary function is to safely transfer digital signals from hazardous locations to safe area control systems while providing galvanic isolation and line fault detection.What types of inputs are compatible with this device?The KFD2-ST3-Ex2 is compatible with both NAMUR sensors and dry contacts.What does SIL 2 certified mean for this product?SIL 2 certification according to IEC/EN 61508 signifies that the device meets high safety integrity levels for use in critical safety instrumented systems.How is the operating mode configured?The operating mode is easily configured using DIP switches located on the device.What are the benefits of galvanic isolation?Galvanic isolation enhances safety by preventing electrical interference between the input, output, and power supply, thereby protecting the overall system.

🇺🇸 Ships from our Florida warehouse
1-Year PALM Parts Warranty
CONDITION
$606.99
17 in stock

USA — Free FedEx Priority & UPS Ground · Worldwide shipping available

For more quantity please contact Customer Service

Experts Available 24/7 · 365
+1 (689) 263-1985
sales@palmpartssolution.com

Fast Shipping

Dispatched quickly on in-stock items via UPS, FedEx & DHL worldwide.

Availability

Thousands of parts in stock — ready for immediate dispatch from Florida.

Payment Flexibility

AMEX, Visa, MasterCard, PayPal, Discover and wire transfer accepted.

PRODUCT DETAILS

Pepperl+Fuchs KFD2-ST3-Ex2

Overview

This is a genuine Pepperl+Fuchs component from the Isolators & Barriers family. PalmPartsSolution stocks it in new, refurbished, and surplus condition with tested warranty and same-day shipping on in-stock units.

Whether you are sourcing a like-for-like replacement for an existing installation, an emergency spare to keep a line running, or a qualified part for a new build, our team can confirm availability, revision, and lead time before you order.

Key Features

  • Genuine Pepperl+Fuchs catalog part
  • Tested before shipment
  • Backed by PalmPartsSolution warranty
  • Cross-reference and revision assistance available
  • Compatible with the broader Pepperl+Fuchs automation ecosystem
  • Engineered to integrate inside Isolators & Barriers installations

Compatibility

When ordering, match the full catalog/part number, hardware revision, and firmware revision called out by your Pepperl+Fuchs equipment. Where applicable, confirm:

  • Input/output voltage and current rating
  • Communication protocol and network role
  • Mounting form factor and footprint
  • Operating temperature, humidity, and IP rating
  • Required certifications (UL, CE, ATEX, marine, etc.)

Not sure which revision you need? Send us the catalog number on the nameplate and we will confirm the correct match.

Replacement Information

Three ways to source this part through PalmPartsSolution:

  1. Exact replacement — same Pepperl+Fuchs catalog number, new or refurbished, tested and warrantied
  2. Form-fit-function equivalent — alternate revision or build that drops in without code changes
  3. Engineered migration — current-generation Pepperl+Fuchs platform with documented conversion notes for the Isolators & Barriers family

Contact our engineering team if you need help choosing between these tracks.

Technical Specifications

  • Signal Type: Digital Input
  • Input Connections: Terminals 1+, 2+, 3- (Channel I); 4+, 5+, 6- (Channel II)
  • Output Connections: Output I: terminal 7+; Output II: terminal 9+
  • Open Circuit Voltage/Short-Circuit Current: Approximately 10 V DC / approximately 8 mA
  • Switching Point/Hysteresis: 1.2–2.1 mA / approximately 0.2 mA
  • Line Fault Detection (LFD) Thresholds: Breakage: I ≤ 0.1 mA; Short-Circuit: I ≥ 6.5 mA
  • Response Time: ≤200 µs
  • Switching Frequency: ≤5 kHz
  • Rated Output Voltage: 30 V DC
  • Rated Output Current: 100 mA
  • Signal Level (Output): 1-Signal: (Supply voltage) - 3 V max. for 100 mA; 0-Signal: Blocked output (off-state current ≤10 µA)
  • Galvanic Isolation: Input/Output and Input/Power Supply: Reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V_eff
  • Indicators: LEDs for power supply, output status, and line fault alerts
  • Configuration: DIP switches located on the device
  • Mounting: 35 mm DIN rail (EN 60715)
  • Dimensions (W×H×D): 20 × 119 × 115 mm
  • Protection Class: IP20
  • Ambient Temperature Range: -20 °C to +60 °C
  • Weight: Approximately 150 g
  • Part Number: 262111

Applications

  • Process Automation Systems: Essential for dependable signal transfer in sophisticated control loops.
  • Chemical and Petrochemical Industries: Designed to meet the stringent safety requirements of potentially explosive atmospheres.
  • Oil and Gas Facilities: Ensures secure operation and monitoring in both onshore and offshore environments.
  • Pharmaceutical Manufacturing: Crucial for maintaining safety and operational integrity in sensitive production processes.
  • Water and Wastewater Treatment Plants: Provides reliable signal isolation in critical infrastructure.

Why Choose the KFD2-ST3-Ex2?

Opting for the Pepperl+Fuchs KFD2-ST3-Ex2 means investing in an isolated barrier that prioritizes safety, reliability, and versatility. Its SIL 2 certification assures integrity in critical safety instrumented systems, while advanced features like line fault detection minimize downtime and enhance diagnostic capabilities. The compact design and broad operating temperature range make it suitable for diverse industrial settings. With global compliance and flexible configuration options, this device offers a robust solution for securing digital signal transmission in hazardous areas.

Availability & Shipping

  • In stock: KFD2-ST3-Ex2 ready for immediate dispatch from our Florida warehouse.
  • Free USA shipping: FedEx Priority (2–5 business days) and UPS Ground (3–5 business days). Expedited options available at checkout.
  • Worldwide delivery: FedEx International Priority (1–5 days), UPS International Priority (3–5 days), and USPS International (5–10 days) — rates calculated at checkout.
  • Bulk pricing: Volume discounts on request — contact our sales team for quantity quotes.
  • Buy with confidence: Every KFD2-ST3-Ex2 ships with a 1-Year PALM Parts warranty and a 30-day return window.
SUPPORT

Frequently Asked Questions — Pepperl+Fuchs

Its primary function is to safely transfer digital signals from hazardous locations to safe area control systems while providing galvanic isolation and line fault detection.

Machine down? We ship parts the same day.

New, surplus, and refurbished Pepperl+Fuchs inventory in stock. Request a quote or speak directly with an automation specialist for emergency sourcing.

CUSTOMER REVIEWS

What Verified Buyers Say

No reviews yet for this product. Be the first verified buyer to share your experience — we email a review invitation after every purchase.

Independent Supplier Notice

PALM Parts Solution operates as an independent industrial automation supplier and is not an authorized distributor or affiliate of any listed manufacturer or brand name. Manufacturer trademarks and product names are used solely for identification purposes. Original manufacturer warranties do not apply. All products sold by PALM Parts are backed by our own 1-year warranty.

Product Condition & Firmware

All products are sold as new unless stated otherwise. Original manufacturer packaging may show signs of handling, storage, or shelf wear. Date codes and series may vary from current factory production. PALM Parts does not guarantee the presence, version, or compatibility of any firmware on PLC or automation products.

Are you an Electrical Distributor?Learn more about our distributor program

PALM Parts Solution sells used surplus products. PALM Parts Solution is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by PALM Parts Solution come with PALM Parts Solution's 1-Year Warranty and do not come with the original manufacturer's warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.

Read full disclaimer →